THE USE OF HYDROSOL HEXACIANFERRATE (II) FERRUM (III) FOR DEVELOPING DIAGNOSTIC LATERAL FLOW TESTS
- Authors: Skopinskaya S.N.1, Yarkov S.P.1, Zlobin V.N.1, Valiev K.K.2
-
Affiliations:
- Federal state unitary enterprise «State scientific research institute of biological engineering» Federal medical-biology agency, Moscow
- Institute of applied mechanics Russian academy of science, Moscow
- Issue: Vol 67, No 3 (2012)
- Pages: 80-85
- Section: SHORT MESSAGES
- Published: 23.03.2012
- URL: https://vestnikramn.spr-journal.ru/jour/article/view/337
- DOI: https://doi.org/10.15690/vramn.v67i3.190
- ID: 337
Cite item
Full Text
Abstract
On the basis of synthesized negatively charged hydrosol hexacianferrate (II) ferrum (III) (HCFF) by diameter 10–20 нм are received stable conjugates with antibodies and antigens glycoprotein and lipopolysaccharide (LPS) nature. Synthesized hydrosol (HCFF) is new type of a disperse phase in the lateral flow assay. Conjugates mentioned above were applied for construction lateral flow tests-systems for revealing cholera toxin, the rabbit antibodies to recombinant glycoproteine complex from Micobaсterium tuberculosis H37 Rv, human immunoglobulin, LPS antigens S. typhimurium, S. enteritidis. Developed lateral flow tests-systems had high analysis speed (5–7 min), good specificity and sensitivity: on cholera toxin of 2,0 ug / ml, on LPS antigens S. typhimurium, S. enteritidis 0,5 ug / ml.
About the authors
S. N. Skopinskaya
Federal state unitary enterprise «State scientific research institute of biological engineering» Federal medical-biology agency, Moscow
Author for correspondence.
Email: niibp@dol.ru
кандидат биологических наук, ведущий научный сотрудник ФГУП Государственного научно-исследовательского института биологического приборостроения Федерального медико- биологического агентства России Адрес: 125424, Москва, Волоколамское шоссе, д. 75, к. 1 Тел./факс: (495) 491- 73-72 Россия
S. P. Yarkov
Federal state unitary enterprise «State scientific research institute of biological engineering» Federal medical-biology agency, Moscow
Email: niibp@dol.ru
доктор биологических наук, начальник отдела спектральных методов анализа ФГУП Государственного научно-исследовательского института биологического приборостроения Федерального медико- биологического агентства России Адрес: 125424, Москва, Волоколамское шоссе, д. 75, к. 1 Тел./факс: (495) 491- 73-72 Россия
V. N. Zlobin
Federal state unitary enterprise «State scientific research institute of biological engineering» Federal medical-biology agency, Moscow
Email: niibp@dol.ru
доктор технических наук, профессор, директор ФГУП Государственного научно- исследовательского института биологического приборостроения Федерального медико-биологического агентства России Адрес: 125424, Москва, Волоколамское шоссе, д. 75, к. 1 Тел./факс: (495) 491- 73-72 Россия
Kh. Kh. Valiev
Institute of applied mechanics Russian academy of science, Moscow
Email: hhvlv@mail.ru
кандидат физико-математических наук, старший научный сотрудник Отдела механики структурированных и гетерогенных сред ФГБУ науки Института прикладной механики Российской академии наук Адрес: 125040, Москва, Ленинградский проспект, д. 7 Тел.: (495) 946-17-64 Россия
References
- Lateral flow immunoassay / Ed. R.C. Wong, H.Y. Tse. N.-Y.: Humana Press a part of Springer. Science&Business Media. 2009. 430 р.
- Chandler J., Gurmin T., Robinson N. The place of gold in rapid tests. IVD Technology. 2000; 6: 37–49.
- Van Amerongen A., Wiechers J.H., Brendsen L.B. Colloid carbon particles of a new label for rapid immunochemical test methods: quantative computer image analyses of results. J. Biotecnol. 1993; 30 (2): 185–195.
- Chan W.C.W., Nie S. Quantum dots: a primer. Appl. Spectroscopy. 2002; 56: 16A.
- Niedbala R., Feindt H., Kardos K. Detection of analytes by immunoassay using up-converting phosphors technology. Anal. Biochem. 2001; 293: 22–30.
- La Borde R.T., O, Farell B. Paramagnetic particles detection in lateral flow assays. IVD Technology. 2002; April issue: 36.
- Ahn-Yoon S., DeCory T.R., Baeumner A.J., Durst R.A. Ganglioside-liposome immunoassay for the ultresensitive detection of cholera toxin. Anal. Chem. 2003; 75: 2256–2261.
- Iarkov S.P., Skopinskaia S.N., Shilenko I.V., Zlobin V.N. Liuminescentny`i` immunokhromatograficheskii` analiz antigenov miqroorganizmov. Vestn. RAMN. 2009; 3: 20–26.
- Iarkov S.P., Shilenko I.V. Primenenie immunokhromatografii dlia vy`iavleniia patogenov i diagnostiki zabolevanii`. V qn.: Sovremenny`e metody` indikatcii patogenov i toksinov v ob``ektakh okruzhaiushchei` sredy` i diagnostiqi sotcial`no-znachimy`kh infektcionny`kh zabolevanii` dlia obespecheniia himicheskoi` i biologicheskoi` bezopasnosti /pod red. V.N. Zlobina. Moskva. 2010. S. 57–118.
- Orlova O.Iu., Meshandin A.G. Sopostavlenie razlichny`kh vidov tverdy`kh faz pri sinteze gidrozol`ny`kh immunohimicheskikh diagnostikumov. Viatsqii` meditcinsqii` vestneyq. 2002; 3 (12): 61–65.
- Ling S. Study on immunosensor based on gold nanoparticles / chitosan and MnO2 nanoparticles composite membrane / Prussian blue modified gold electrode. Bioprocess Biosyst. Eng. 2009; 32 (3): 407–414.
- Sergeeva N.G., Iushkova I.K. Laboratorny`i` praktikum po kolloidnoi` himii. Nizhnii` Tagil. 2005. 50 s.
- Pis`menko V.T., Kaliukova E.N. Kolloidnaia himiia: Metodicheskie uqazaniia. Ul`ianowsq: UlGTU. 2003. 72
- Iarkov S.P., Tret`iakov S.I., Basharova L.A., Zlobin V.N. Indikatciia vozbuditelei` osobo opasny`kh zabolevanii` s pomoshch`iu immunokhromatografii i videotcifrovogo analiza. Vestn. RAMN. 2007; 12: 22–26.
- Vorob`ev A.A. Mikrobiologiia i immunologiia. M.: Meditcina. 1999. 464 c.